PlainEnviro

Non-transient non-community water system · California

Gregori High School drinking water

Gregori High School (CA5000568) is a non-transient non-community water system in California serving 2,000 people from groundwater. In the 10 years to the 2026 third-quarter report, EPA records no health-based violation. Its latest lead 90th percentile (monitoring period beginning January 2024) was 0.069 mg/L, above the 0.015 mg/L action level that requires a system to act. (EPA SDWA data, October 14, 2026.)

Check this record at EPA: ECHO drinking water report for CA5000568

2,000people served

0health-based violations, 10 years

0violations still open

0.069mg/Llead, 90th percentile (period from 2024)

Is the water from Gregori High School safe to drink?

Gregori High School had no health-based violation in the 10 years to October 2026: EPA records no time its water broke a limit or a required treatment step.

In California, 32% of the 2,920 active community systems had a health-based violation in the same 10 years.

In its measured results, its latest lead 90th percentile (period beginning January 2024) was 0.069 mg/L, above the 0.015 mg/L action level. It draws on groundwater for 2,000 people.

This is Gregori High School's compliance record, not a test of the water at your tap: what the records cannot tell you, and who can.

Source: EPA Safe Drinking Water Information System (SDWIS), federal data download, quarter 2026Q3, released October 14, 2026. Confirm in EPA ECHO drinking water search.

What violations does EPA record for Gregori High School?

EPA records no violation of any kind for Gregori High School since October 2016.

Source: SDWIS violations and enforcement, quarter 2026Q3; health-based means a maximum contaminant level, residual disinfectant level or treatment technique was not met.

How much lead and copper is in Gregori High School's tap samples?

Lead, 90th percentile of tap samples (period beginning January 2024)0.069 mg/L Above the action level

Over the action level (Gregori High School's result is a 90th percentile: what that is), a system must treat the water to make it less corrosive, tell the public and replace lead lines. The Lead and Copper Rule Improvements (in effect since December 30, 2024) lower the lead action level to 0.010 mg/L from November 1, 2027.

Source: SDWIS lead and copper sample summaries (90th percentiles), quarter 2026Q3; Lead and Copper Rule Improvements: Federal Register, published October 30, 2024, effective December 30, 2024; 40 CFR 141.80(a)(4)(i) keeps 0.015 mg/L until November 1, 2027 and 141.80(c)(1) sets 0.010 mg/L from then (eCFR); both read November 11, 2026.

Who does Gregori High School serve, and where does its water come from?

Gregori High School is a non-transient non-community water system; EPA's inventory lists its owner type as local government, on EPA's inventory since 2011.

Community systems publish an annual water quality report (Consumer Confidence Report); a school or workplace system reports to its own users; how to find yours (EPA).

Source: SDWIS water system inventory and geographic areas served, quarter 2026Q3.

What other environmental records are in Stanislaus County?

The TRI facilities in Stanislaus County that reported the most toxic releases:

  1. Blue Diamond Growers 45,555 pounds
  2. California Dairies Inc Turlock 44,921 pounds
  3. Darling Ingredients Inc 35,290 pounds
  4. Saputo Cheese USA Inc 31,123 pounds
  5. California Dairies Inc Turlock North 24,865 pounds

Superfund sites in Stanislaus County: Riverbank Army Ammunition Plant (on the National Priorities List); Valley Wood Preserving, Inc. (on the National Priorities List); Modesto Ground Water Contamination (on the National Priorities List).

A facility or site in the same county is not evidence that it affects this system's water; source-water protection is assessed by the state.

Source: EPA Toxics Release Inventory 2024 and EPA SEMS National Priorities List, as of October 28, 2026.

Sources: the EPA files behind this page
  • EPA Safe Drinking Water Act data download (SDWIS), quarter 2026Q3, October 14, 2026: echo.epa.gov
  • EPA Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) occurrence data, final data, August 2026: www.epa.gov
  • EPA Lead and Copper Rule and Lead and Copper Rule Improvements: www.epa.gov
  • EPA PFAS National Primary Drinking Water Regulation (2024) and the May 2026 proposal: www.epa.gov
  • EPA: find your local Consumer Confidence Report: www.epa.gov
  • EPA Toxics Release Inventory basic data files, reporting years 2019-2024, reporting year 2024 processed November 5, 2025: www.epa.gov
  • EPA SEMS: all final, proposed and deleted NPL sites with dates, category and contaminants, report dated October 28, 2026: www.epa.gov