PlainEnviro

Non-transient non-community water system · Indiana

Laville Jr. & Sr. High School drinking water

Laville Jr. & Sr. High School (IN2710815) is a non-transient non-community water system in Lakeville, IN serving 675 people from groundwater. In the 10 years to the 2026 third-quarter report, EPA records 2 health-based violations and 6 monitoring, reporting or notice violations. Its latest lead 90th percentile (monitoring period beginning January 2026) was below the detection limit. UCMR 5 tests (2023-2025) found no PFAS above the reporting levels. (EPA SDWA data, October 14, 2026.)

Check this record at EPA: ECHO drinking water report for IN2710815

675people served

2health-based violations, 10 years

0violations still open

NDlead, 90th percentile: below detection (period from 2026)

0PFAS detected (UCMR 5)

Is the water from Laville Jr. & Sr. High School safe to drink?

Laville Jr. & Sr. High School had 2 health-based violations in the 10 years to October 2026: a required treatment step not met. Every violation since October 2016 is resolved or archived. Its full SDWIS record, older years included, holds 19 violations of every kind.

In Indiana, 28% of the 767 active community systems had a health-based violation in the same 10 years.

In its measured results, its latest lead 90th percentile (period beginning January 2026) was below the detection limit; EPA's UCMR 5 survey tested it for 30 substances and detected no PFAS. It draws on groundwater for 675 people.

This is Laville Jr. & Sr. High School's compliance record, not a test of the water at your tap: what the records cannot tell you, and who can.

Source: EPA Safe Drinking Water Information System (SDWIS), federal data download, quarter 2026Q3, released October 14, 2026. Confirm in EPA ECHO drinking water search.

What violations does EPA record for Laville Jr. & Sr. High School?

EPA records 8 violations for Laville Jr. & Sr. High School since October 2016: 6 monitoring and reporting and 2 treatment technique.

Violations since October 2016, newest first
Contaminant or ruleKindCompliance periodStatus
Lead and Copper RuleMonitoring and reportingsince January 2025Resolved
Lead and Copper RuleTreatment technique (health-based)since July 2023Resolved
Lead and Copper RuleMonitoring and reportingJuly 2023 to December 2023Resolved
Lead and Copper RuleMonitoring and reportingsince June 2023Resolved
Lead and Copper RuleMonitoring and reportingsince July 2022Resolved
Lead and Copper RuleTreatment technique (health-based)since July 2022Resolved
Lead and Copper RuleMonitoring and reportingJanuary 2022 to June 2022Resolved
Lead and Copper RuleMonitoring and reportingsince January 2020Resolved
Violations by year the compliance period began, Laville Jr. & Sr. High School (violations)
0001033010
Violations by year the compliance period began, Laville Jr. & Sr. High School
20170 violations
20180 violations
20190 violations
20201 violation
20210 violations
20223 violations
20233 violations
20240 violations
20251 violation
20260 violations

Source: SDWIS violations and enforcement, quarter 2026Q3; health-based means a maximum contaminant level, residual disinfectant level or treatment technique was not met.

How much lead and copper is in Laville Jr. & Sr. High School's tap samples?

Lead, 90th percentile of tap samples (period beginning January 2026)0.0 mg/L Below detection
Copper, 90th percentile (period beginning January 2023)1.36 mg/L Above the action level

Over the action level (Laville Jr. & Sr. High School's result is a 90th percentile: what that is), a system must treat the water to make it less corrosive, tell the public and replace lead lines. The Lead and Copper Rule Improvements (in effect since December 30, 2024) lower the lead action level to 0.010 mg/L from November 1, 2027.

Source: SDWIS lead and copper sample summaries (90th percentiles), quarter 2026Q3; Lead and Copper Rule Improvements: Federal Register, published October 30, 2024, effective December 30, 2024; 40 CFR 141.80(a)(4)(i) keeps 0.015 mg/L until November 1, 2027 and 141.80(c)(1) sets 0.010 mg/L from then (eCFR); both read November 11, 2026.

Did EPA find PFAS in Laville Jr. & Sr. High School's water?

None of the 30 analytes tested was detected in any sample: 11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFBA, PFBS, PFDA, PFDoA, PFEESA, PFHpA, PFHpS, PFHxA, PFHxS, PFMBA, PFMPA, PFNA, PFOA, PFOS, PFPeA, PFPeS, PFTA, PFTrDA, PFUnA, lithium.

UCMR 5 measured 29 PFAS and lithium in every community and non-transient non-community system serving 3,300 people or more (and a sample of 800 smaller ones) from 2023 to 2025. Its results show what was in the water; they are not compliance samples. The 2024 limits (PFOA and PFOS 4.0 ng/L; PFHxS, PFNA and HFPO-DA 10 ng/L) apply as running annual averages from 2029. In May 2026 EPA proposed keeping the PFOA and PFOS limits with an option to extend the date to 2031, and withdrawing the other three. PFAS results across the country

Source: EPA Fifth Unregulated Contaminant Monitoring Rule (UCMR 5), final occurrence data released August 2026 (file dated October 15, 2026); 1 ng/L = 0.001 µg/L; 2024 PFAS limits: 40 CFR 141.61(c)(2) (eCFR); EPA proposals of May 2026: Federal Register documents 2026-10085 and 2026-10086 (May 20, 2026), no final rule; UCMR 5 results are survey, not compliance, data: UCMR 5 Data Summary (July 2026) and EPA's PFAS compliance quick reference guide (January 2025); all read November 11, 2026.

Who does Laville Jr. & Sr. High School serve, and where does its water come from?

Laville Jr. & Sr. High School is a non-transient non-community water system; EPA's inventory lists its owner type as local government, on EPA's inventory since 1989.

It reports serving Lakeville, in St. Joseph county.

Community systems publish an annual water quality report (Consumer Confidence Report); a school or workplace system reports to its own users; how to find yours (EPA).

Source: SDWIS water system inventory and geographic areas served, quarter 2026Q3.

What other environmental records are in St. Joseph County?

The TRI facilities in St. Joseph County that reported the most toxic releases:

  1. I/N Kote 142,888 pounds
  2. Sampson Fiberglass Inc. 49,834 pounds
  3. Molding Products LLC 36,865 pounds
  4. Suzuki Garphyttan Corp 34,409 pounds
  5. Ultra/Glas of Lakeville Inc 24,885 pounds

Superfund sites in St. Joseph County: Douglas Road/Uniroyal, Inc., Landfill (on the National Priorities List); Beck's Lake (on the National Priorities List); Galen Myers Dump/Drum Salvage (on the National Priorities List); Whiteford Sales & Service Inc./Nationalease (deleted from the list).

A facility or site in the same county is not evidence that it affects this system's water; source-water protection is assessed by the state.

Source: EPA Toxics Release Inventory 2024 and EPA SEMS National Priorities List, as of October 28, 2026.

Sources: the EPA files behind this page
  • EPA Safe Drinking Water Act data download (SDWIS), quarter 2026Q3, October 14, 2026: echo.epa.gov
  • EPA Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) occurrence data, final data, August 2026: www.epa.gov
  • EPA Lead and Copper Rule and Lead and Copper Rule Improvements: www.epa.gov
  • EPA PFAS National Primary Drinking Water Regulation (2024) and the May 2026 proposal: www.epa.gov
  • EPA: find your local Consumer Confidence Report: www.epa.gov
  • EPA Toxics Release Inventory basic data files, reporting years 2019-2024, reporting year 2024 processed November 5, 2025: www.epa.gov
  • EPA SEMS: all final, proposed and deleted NPL sites with dates, category and contaminants, report dated October 28, 2026: www.epa.gov