PlainEnviro

Drinking-water contaminant · UCMR 5

Perfluorononanoic acid (PFNA) in drinking water

Perfluorononanoic acid (PFNA) (SDWIS code 2804) has a federal maximum contaminant level (2024 rule, enforceable from 2029) of 10 ng/L. In the 10 years to the 2026 third-quarter report, EPA records no health-based violation for it. In UCMR 5, EPA tested 10,307 systems for it; 83 detected it and 21 had a result above the 2024 limit. (EPA SDWA data, October 14, 2026; UCMR 5.)

Check this record at EPA: EPA National Primary Drinking Water Regulations

10ng/Lmaximum contaminant level (2024 rule, enforceable from 2029)

0health-based violations, 10 years

0systems with one

0violations open now

83of 10,307 systems detected it (UCMR 5)

How does perfluorononanoic acid (PFNA) compare with other drinking-water contaminants?

In UCMR 5 it was detected at 0.8% of the 10,307 systems tested, 11th of 30 analytes by systems detecting. 21 systems had a result above the 2024 limit of 10 ng/L.

Source: Computed by PlainEnviro from SDWIS quarter 2026Q3 and the UCMR 5 final occurrence data.

What is the federal limit for perfluorononanoic acid (PFNA) in drinking water?

The federal maximum contaminant level (2024 rule, enforceable from 2029) for perfluorononanoic acid (PFNA) is 10 ng/L, under 89 FR 32532 (2024), 40 CFR part 141. The limit was set in the April 2024 PFAS rule and applies as a running annual average from 2029; it is proposed for withdrawal by EPA in May 2026.

Every federal drinking-water limit

Source: 40 CFR part 141 (National Primary Drinking Water Regulations), as cited; EPA Safe Drinking Water Information System (SDWIS), federal data download, quarter 2026Q3, released October 14, 2026.

How many water systems violated the perfluorononanoic acid (PFNA) rules in 10 years?

EPA records no violation for perfluorononanoic acid (PFNA) with a compliance period beginning since October 1, 2016.

Source: EPA Safe Drinking Water Information System (SDWIS), federal data download, quarter 2026Q3, released October 14, 2026; Health-based means a maximum contaminant level, residual disinfectant level or treatment technique was not met.

How much PFNA did EPA find in tap water systems?

EPA tested 10,307 public water systems for PFNA from 2023 to 2025. 83 (under 1%) detected it at or above the reporting level, systems serving 8,867,904 people. In 21 the highest result was above the 2024 limit of 10 ng/L, systems serving 1,442,048 people. UCMR 5 results come from EPA's national survey, not compliance samples, so a result above a limit level is not a violation; under the 2024 rule, compliance is judged from 2029 on running annual averages of compliance samples.

Highest UCMR 5 PFNA results (ng/L) (25 of 83 systems that detected it)
Water systemStatePeople servedHighest resultSamples detected
Emmaus Borough Public WaterPA14,00099.84 of 8
East Greenwich Twp Water DeptNJ9,90073.31 of 10
Capitol Water CorpID9,000514 of 8
Locust Valley WDNY7,50029.62 of 10
Pequenakonck Elementary SchoolNY70026.41 of 2
City of PflugervilleTX63,46425.24 of 8
Manville WSCTX39,64824.33 of 20
Quakertown BoroPA12,800242 of 14
Palmerton Municipal AuthorityPA7,00021.12 of 4
Georgetown Water DepartmentDE7,259203 of 4
Manhasset Lakeville WDNY43,000191 of 19
Westville Water DepartmentNJ6,00016.72 of 2
Emerald Coast Utilities Authority (ECUA)FL242,17216.22 of 54
Ho Ho Kus Water DeptNJ4,06016.15 of 8
West Deptford Twp Water DeptNJ22,000167 of 14
Brooklawn Water DepartmeNJ2,30015.31 of 2
Ambler Boro Water DeptPA20,00013.53 of 20
Fallsburg Who-LS-SFNY7,85013.12 of 15
Aqua PA Main SystemPA822,600127 of 50
Veolia Water Delaware, IncDE100,49511.68 of 8
Potrero Elementary SchoolCA30010.22 of 2
City of GridleyCA7,2699.92 of 10
Veolia Water BethelPA7,8099.75 of 16
Williamsport Mun Water AuthPA51,0009.73 of 4
Eagle Point Tank FarmNJ9092 of 2

UCMR 5 results show what was in the water when sampled; they are not compliance samples. PFAS results by state

Source: EPA Fifth Unregulated Contaminant Monitoring Rule (UCMR 5), final occurrence data released August 2026 (file dated October 15, 2026); 1 ng/L = 0.001 µg/L.

Do industrial facilities release perfluorononanoic acid (PFNA)?

Facilities also report releases of this substance to the Toxics Release Inventory: Perfluorononanoic acid. A release to air, water or land is not a measurement of any water system's supply.

What do these records show, and what not?

States report each public water system's violations to EPA, which publishes them quarterly. A violation is a compliance record, not a test of the water in your tap; your utility's annual water quality report (the Consumer Confidence Report) and a certified laboratory answer that. Counts here are violations with a compliance period beginning on or after October 1, 2016. How the data is checked

Sources: the EPA files behind this page
  • EPA Safe Drinking Water Act data download (SDWIS), quarter 2026Q3, October 14, 2026: echo.epa.gov
  • EPA Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) occurrence data, final data, August 2026: www.epa.gov
  • EPA Lead and Copper Rule and Lead and Copper Rule Improvements: www.epa.gov
  • EPA PFAS National Primary Drinking Water Regulation (2024) and the May 2026 proposal: www.epa.gov
  • EPA: find your local Consumer Confidence Report: www.epa.gov