Non-transient non-community water system · Mississippi
Ingalls Shipbuilding drinking water
Ingalls Shipbuilding (MS0300010) is a non-transient non-community water system in Mississippi serving 12,000 people from groundwater. In the 10 years to the 2026 third-quarter report, EPA records no health-based violation. Its latest lead 90th percentile (monitoring period beginning January 2022) was 0.003 mg/L, below the 0.015 mg/L action level that requires a system to act. UCMR 5 tests (2023-2025) found no PFAS above the reporting levels. (EPA SDWA data, October 14, 2026.)
Check this record at EPA: ECHO drinking water report for MS0300010
12,000people served
0health-based violations, 10 years
0violations still open
0.003mg/Llead, 90th percentile (period from 2022)
0PFAS detected (UCMR 5)
Is the water from Ingalls Shipbuilding safe to drink?
Ingalls Shipbuilding had no health-based violation in the 10 years to October 2026: EPA records no time its water broke a limit or a required treatment step. Its full SDWIS record, older years included, holds 4 violations of every kind.
In Mississippi, 29% of the 1,015 active community systems had a health-based violation in the same 10 years.
In its measured results, its latest lead 90th percentile (period beginning January 2022) was 0.003 mg/L, below the 0.015 mg/L action level; EPA's UCMR 5 survey tested it for 30 substances and detected no PFAS. It draws on groundwater for 12,000 people.
This is Ingalls Shipbuilding's compliance record, not a test of the water at your tap: what the records cannot tell you, and who can.
Source: EPA Safe Drinking Water Information System (SDWIS), federal data download, quarter 2026Q3, released October 14, 2026. Confirm in EPA ECHO drinking water search.
What violations does EPA record for Ingalls Shipbuilding?
EPA records no violation of any kind for Ingalls Shipbuilding since October 2016 (its record holds 4 older violations).
Source: SDWIS violations and enforcement, quarter 2026Q3; health-based means a maximum contaminant level, residual disinfectant level or treatment technique was not met.
How much lead and copper is in Ingalls Shipbuilding's tap samples?
Over the action level (Ingalls Shipbuilding's result is a 90th percentile: what that is), a system must treat the water to make it less corrosive, tell the public and replace lead lines. The Lead and Copper Rule Improvements (in effect since December 30, 2024) lower the lead action level to 0.010 mg/L from November 1, 2027.
Source: SDWIS lead and copper sample summaries (90th percentiles), quarter 2026Q3; Lead and Copper Rule Improvements: Federal Register, published October 30, 2024, effective December 30, 2024; 40 CFR 141.80(a)(4)(i) keeps 0.015 mg/L until November 1, 2027 and 141.80(c)(1) sets 0.010 mg/L from then (eCFR); both read November 11, 2026.
Did EPA find PFAS in Ingalls Shipbuilding's water?
| Analyte | Highest result | Reporting level | 2024 limit | Unit | Samples detected | Qualifier |
|---|---|---|---|---|---|---|
| lithium | 18.3 | 9 | none | µg/L | 2 of 2 | Detected |
Not detected in any sample (29 of the 30 analytes tested): 11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFBA, PFBS, PFDA, PFDoA, PFEESA, PFHpA, PFHpS, PFHxA, PFHxS, PFMBA, PFMPA, PFNA, PFOA, PFOS, PFPeA, PFPeS, PFTA, PFTrDA, PFUnA.
UCMR 5 measured 29 PFAS and lithium in every community and non-transient non-community system serving 3,300 people or more (and a sample of 800 smaller ones) from 2023 to 2025. Its results show what was in the water; they are not compliance samples. The 2024 limits (PFOA and PFOS 4.0 ng/L; PFHxS, PFNA and HFPO-DA 10 ng/L) apply as running annual averages from 2029. In May 2026 EPA proposed keeping the PFOA and PFOS limits with an option to extend the date to 2031, and withdrawing the other three. PFAS results across the country
Source: EPA Fifth Unregulated Contaminant Monitoring Rule (UCMR 5), final occurrence data released August 2026 (file dated October 15, 2026); 1 ng/L = 0.001 µg/L; 2024 PFAS limits: 40 CFR 141.61(c)(2) (eCFR); EPA proposals of May 2026: Federal Register documents 2026-10085 and 2026-10086 (May 20, 2026), no final rule; UCMR 5 results are survey, not compliance, data: UCMR 5 Data Summary (July 2026) and EPA's PFAS compliance quick reference guide (January 2025); all read November 11, 2026.
Who does Ingalls Shipbuilding serve, and where does its water come from?
Ingalls Shipbuilding is a non-transient non-community water system; EPA's inventory lists its owner type as private, on EPA's inventory since 1979.
Community systems publish an annual water quality report (Consumer Confidence Report); a school or workplace system reports to its own users; how to find yours (EPA).
Source: SDWIS water system inventory and geographic areas served, quarter 2026Q3.
What other environmental records are in Jackson County?
The TRI facilities in Jackson County that reported the most toxic releases:
- Chevron Products Co Pascagoula Refinery 2.0 million pounds
- Mississippi Power Co - Plant Daniel 231,785 pounds
- Ingalls Shipbuilding Pascagoula Operations 191,345 pounds
- Enterprise Gas Processing LLC Pascagoula Gas Processing Pla 131,801 pounds
- Bollinger Mississippi Repair LLC 53,064 pounds
Superfund sites in Jackson County: Mississippi Phosphates Corporation (on the National Priorities List).
A facility or site in the same county is not evidence that it affects this system's water; source-water protection is assessed by the state.
Source: EPA Toxics Release Inventory 2024 and EPA SEMS National Priorities List, as of October 28, 2026.
Sources: the EPA files behind this page
- EPA Safe Drinking Water Act data download (SDWIS), quarter 2026Q3, October 14, 2026: echo.epa.gov
- EPA Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) occurrence data, final data, August 2026: www.epa.gov
- EPA Lead and Copper Rule and Lead and Copper Rule Improvements: www.epa.gov
- EPA PFAS National Primary Drinking Water Regulation (2024) and the May 2026 proposal: www.epa.gov
- EPA: find your local Consumer Confidence Report: www.epa.gov
- EPA Toxics Release Inventory basic data files, reporting years 2019-2024, reporting year 2024 processed November 5, 2025: www.epa.gov
- EPA SEMS: all final, proposed and deleted NPL sites with dates, category and contaminants, report dated October 28, 2026: www.epa.gov