According to the EPA Superfund Enterprise Management System, Horton Iron and Metal in Wilmington, NC is listed with NPL status NPL Site. Its Hazard Ranking System (HRS) score is 48.03. The public extract catalogs 135 contaminant records for this site. NPL listing is a cleanup-authority designation, not a measured health-risk score.

View saved records

Superfund National Priorities List inclusion (status and HRS score shown above) is the EPA's formal designation that a contaminated site qualifies for long-term federal cleanup authority under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). A federal-facility classification means the site is owned or operated by a federal agency, which routes cleanup responsibility differently than a privately owned site.

"Construction Complete" (status shown above) is an EPA milestone marking that the physical remedy work is finished, not that the site has exited EPA oversight; long-term monitoring can continue afterward. Deletion from the NPL is a separate, later step the EPA takes only once it determines every planned response action is finished.

NPL listing is a cleanup-authority designation in the EPA record, not a quantitative health-risk score. HRS scores of 28.50 or above qualify a site for the NPL under the EPA screening model (toxicity, pathways, waste quantity, and affected population factors). For current site conditions and official community notices, see the EPA Regional Superfund profile and the North Carolina environmental agency.

What is the cleanup status of this Superfund site?

NPL Status
NPL Site
Federal Facility
No
Construction Complete
No
HRS Score
48.03
Deleted from NPL
No

Contaminants

Contaminant Media
1,1'-BIPHENYL Sediment
1,2-DIHYDROACENAPHTHYLENE Sediment
1,2-DIHYDROACENAPHTHYLENE Soil
1-PHENYLETHANONE Sediment
2,4,6-TRICHLOROPHENOL Sediment
2,4-DICHLOROPHENOL Sediment
2,4-DIMETHYLPHENOL Sediment
2,4-DINITROPHENOL Sediment
2,4-DINITROTOLUENE Sediment
2,6-DINITROTOLUENE Sediment
2-CHLORONAPHTHALENE Sediment
2-CHLOROPHENOL Sediment
2-METHYL-4,6-DINITROPHENOL (4,6-DINITRO-O-CRESOL) Sediment
2-METHYLNAPHTHALENE Sediment
2-METHYLNAPHTHALENE Soil
2-METHYLPHENOL (O-CRESOL) Sediment
2-NITROANILINE Sediment
3,5,5-TRIMETHYLCYCLOHEX-2-EN-1-ONE Sediment
4-(4-AMINO-3-CHLOROPHENYL)-2-CHLOROANILINE Sediment
4-CHLORO-3-METHYLPHENOL Sediment
4-CHLOROANILINE Sediment
4-METHYLPHENOL (P-CRESOL) Sediment
4-NITROANILINE Sediment
9H-CARBAZOLE Sediment
9H-FLUORENE Sediment
ACENAPHTHYLENE Sediment
ACENAPHTHYLENE Soil
ALPHA-CHLORDANE Groundwater
ALUMINUM Sediment
ANTHRACENE Sediment
ANTIMONY Groundwater
ANTIMONY Sediment
ANTIMONY Soil
AROCLOR 1016 Sediment
AROCLOR 1221 Sediment
AROCLOR 1232 Sediment
AROCLOR 1242 Sediment
AROCLOR 1248 Groundwater
AROCLOR 1248 Sediment
AROCLOR 1254 Sediment
AROCLOR 1254 Soil
AROCLOR 1260 Sediment
ARSENIC Groundwater
ARSENIC Sediment
ARSENIC Soil
ATRAZINE Sediment
AZEPAN-2-ONE Sediment
BARIUM Groundwater
BARIUM Sediment
BENZALDEHYDE Sediment
BENZO(B)FLUORANTHENE Groundwater
BENZO(B)FLUORANTHENE Sediment
BENZO(B)FLUORANTHENE Soil
BENZO(GHI)PERYLENE Sediment
BENZO(GHI)PERYLENE Soil
BENZO(K)FLUORANTHENE Sediment
BENZO(K)FLUORANTHENE Soil
BENZO[A]ANTHRACENE Groundwater
BENZO[A]ANTHRACENE Sediment
BENZO[A]ANTHRACENE Soil
BENZO[A]PYRENE Groundwater
BENZO[A]PYRENE Sediment
BENZO[A]PYRENE Soil
BERYLLIUM Groundwater
BERYLLIUM Sediment
BIS(2-CHLOROETHOXY) METHANE Sediment
BIS(2-CHLOROETHYL)ETHER Groundwater
BIS(2-CHLOROETHYL)ETHER Sediment
BIS(2-ETHYLHEXYL)PHTHALATE Sediment
BUTYL BENZYL PHTHALATE Sediment
CADMIUM Groundwater
CADMIUM Sediment
CHROMIUM Groundwater
CHROMIUM Sediment
CHROMIUM Soil
CHRYSENE Sediment
CHRYSENE Soil
COBALT Groundwater
COBALT Sediment
COBALT Soil
COPPER Sediment
DI-N-OCTYL PHTHALATE Sediment
DIBENZO(A,H)ANTHRACENE Groundwater
DIBENZO(A,H)ANTHRACENE Sediment
DIBENZO(A,H)ANTHRACENE Soil
DIBENZOFURAN Groundwater
DIBENZOFURAN Sediment
DIBUTYL PHTHALATE Sediment
DIELDRIN Groundwater
DIETHYL PHTHALATE Sediment
FLUORANTHENE Sediment
FLUORANTHENE Soil
HEXACHLORO-1,3-BUTADIENE Sediment
HEXACHLOROBENZENE Groundwater
HEXACHLOROBENZENE Sediment
HEXACHLOROBENZENE Soil
HEXACHLOROCYCLOPENTADIENE Sediment
HEXACHLOROETHANE Sediment
INDENO(1,2,3-CD)PYRENE Groundwater
INDENO(1,2,3-CD)PYRENE Sediment
INDENO(1,2,3-CD)PYRENE Soil
IRON Groundwater
IRON Sediment
IRON Soil
LEAD Groundwater
LEAD Sediment
LEAD Soil
MANGANESE Groundwater
MANGANESE Sediment
MANGANESE Soil
MERCURY Sediment
MERCURY Soil
N,N-DIPHENYLNITROUS AMIDE Sediment
N,N-DIPROPYLNITROUS AMIDE Sediment
NAPHTHALENE Sediment
NAPHTHALENE Soil
NICKEL Groundwater
NICKEL Sediment
NICKEL Soil
NITROBENZENE Sediment
PENTACHLOROPHENOL Sediment
PHENANTHRENE Sediment
PHENANTHRENE Soil
PHENOL Sediment
PYRENE Sediment
PYRENE Soil
SELENIUM Sediment
SILVER Sediment
THALLIUM Groundwater
THALLIUM Sediment
THALLIUM Soil
VANADIUM Groundwater
VANADIUM Sediment
ZINC Groundwater
ZINC Sediment

Location

City
Wilmington
Coordinates
34.2666, -77.9541

Other Superfund Sites in North Carolina

Site Name Status HRS Score
ABC One Hour Cleaners NPL Site 29.11
Aberdeen Contaminated Ground Water NPL Site 50.00
Aberdeen Pesticide Dumps NPL Site 52.70
Barber Orchard NPL Site 70.71
Benfield Industries, Inc. NPL Site 31.67
Blue Ridge Plating Company NPL Site 38.67
Bypass 601 Ground Water Contamination NPL Site 37.93
Camp Lejeune Military Reservation NPL Site 33.13
Cape Fear Wood Preserving NPL Site 34.09
Carolina Transformer Co. NPL Site 33.76

How does this site's HRS score compare in North Carolina?

Of the 42 North Carolina Superfund sites with a scored Hazard Ranking System (HRS) evaluation, Horton Iron and Metal ranks #15 by score (48.03).

Either side of it: Celanese Corp. (Shelby Fiber Operations) (48.98), North Carolina State University (Lot 86, Farm Unit #1) (48.36), Wright Chemical Corporation (48.03), Cristex Drum (48.00)

Frequently Asked Questions

What is the Horton Iron and Metal Superfund site?
Horton Iron and Metal is an active National Priorities List (NPL) Superfund site located in Wilmington, NC. It has a Hazard Ranking System (HRS) score of 48.03 (rank #15 of 42 scored North Carolina sites). Superfund sites are contaminated locations identified by the EPA for long-term cleanup under CERCLA.
What does NPL listing mean for Horton Iron and Metal?
According to the EPA, National Priorities List (NPL) listing designates a site for long-term federal Superfund cleanup authority. It is a programmatic status in the Superfund Enterprise Management System, not a quantitative health-risk score for nearby residents. Construction-complete status is not marked in the EPA record for this site. Site-specific conditions and community guidance are published by EPA Regional Superfund offices and the relevant state environmental agency.
What is the HRS score for Horton Iron and Metal?
Horton Iron and Metal's Hazard Ranking System (HRS) score is 48.03, placing it #15 of 42 North Carolina Superfund sites with a scored HRS evaluation. Sites with a score of 28.50 or greater qualify for the NPL; the model weighs contaminant toxicity, waste quantity, release likelihood, and affected population, and is not a community health diagnosis.
What contaminants are at the Horton Iron and Metal site?
The EPA public Superfund extract catalogs 135 contaminants at Horton Iron and Metal, documented through the remedial investigation process. Counts reflect listed records in that extract, not a complete inventory of every substance ever present.
What is the cleanup status of Horton Iron and Metal?
Horton Iron and Metal is currently NPL Site on the National Priorities List. The EPA Superfund cleanup process includes phases from preliminary assessment through post-construction completion.

NPL listing is a cleanup-authority designation in the EPA record, not a quantitative health-risk score. See Superfund Sites Explained for how the National Priorities List, Hazard Ranking System, and cleanup phases work.

Related