Linemaster Switch Corp.

Verify at EPA Superfund →
NPL Site

Woodstock, CT

Linemaster Switch Corp. is listed in the EPA Superfund Enterprise Management System with an NPL status of NPL Site and a Hazard Ranking System (HRS) score of 33.71. The site is located in Woodstock, CT. Superfund National Priorities List inclusion is the EPA's formal designation that a contaminated site qualifies for long-term federal cleanup authority under the Comprehensive Environmental Response, Compensation, and Liability Act.

EPA Superfund records catalog 50 contaminants associated with this site, documented through the remedial investigation process. Physical construction of the cleanup remedy has been completed, EPA designates this milestone as "Construction Complete."

NPL listing does not, by itself, establish a health risk to nearby residents, it triggers federal authority to investigate, score, and remediate. HRS scores of 28.50 or above qualify a site for the NPL; the ranking weighs contaminant toxicity, release pathways, waste quantity, and affected population. For current site conditions and community health guidance, contact the Connecticut environmental or health agency and the EPA Regional Superfund office listed on the official site profile.

What is the cleanup status of this Superfund site?

NPL Status
NPL Site
Federal Facility
No
Construction Complete
Yes
HRS Score
33.71
Deleted from NPL
No

Contaminants

Contaminant Media
1,1,1-TRICHLOROETHANE Groundwater
1,1,1-TRICHLOROETHANE Soil
1,1,2-TRICHLOROETHANE Groundwater
1,1-DICHLOROETHANE Groundwater
1,1-DICHLOROETHENE Groundwater
1,2-DICHLOROETHANE Groundwater
1,2-DICHLOROETHANE Surface Water
1,2-DICHLOROETHENE (CIS AND TRANS MIXTURE) Groundwater
1,2-DICHLOROPROPANE Groundwater
1-CHLORO-2-ETHENOXYETHANE Groundwater
2-BUTANONE (METHYL ETHYL KETONE) Groundwater
2-HEXANONE Groundwater
4-METHYL-2-PENTANONE (METHYL ISOBUTYL KETONE) Groundwater
ACETONE Groundwater
ACETONE Soil
ARSENIC Groundwater
ARSENIC Soil
ARSENIC Surface Water
BENZENE Groundwater
BERYLLIUM Groundwater
BIS(2-ETHYLHEXYL)PHTHALATE Soil
CADMIUM Groundwater
CADMIUM Soil
CARBON DISULFIDE Groundwater
CARBON TETRACHLORIDE Groundwater
CHLOROETHENE (VINYL CHLORIDE) Groundwater
CHLOROFORM Groundwater
CHLOROFORM Surface Water
CHLOROMETHANE Groundwater
CIS-1,2-DICHLOROETHENE Groundwater
CIS-1,2-DICHLOROETHENE Soil
CIS-1,2-DICHLOROETHENE Surface Water
DIBUTYL PHTHALATE Soil
DICHLORODIFLUOROMETHANE Groundwater
DICHLOROMETHANE (METHYLENE CHLORIDE) Groundwater
ETHYLBENZENE Groundwater
ETHYLBENZENE Soil
LEAD Surface Water
TETRACHLOROETHENE Groundwater
TETRACHLOROETHENE Soil
TOLUENE Groundwater
TOLUENE Soil
TRANS-1,2-DICHLOROETHENE Groundwater
TRICHLOROETHENE Groundwater
TRICHLOROETHENE Soil
TRICHLOROETHENE Surface Water
TRICHLOROFLUOROMETHANE Groundwater
VINYL ACETATE Groundwater
XYLENE (MIXED ISOMERS) Groundwater
XYLENE (MIXED ISOMERS) Soil

Location

City
Woodstock
Coordinates
41.9406, -71.9669

Other Superfund Sites in Connecticut

Site Name Status HRS Score
Barkhamsted-New Hartford Landfill NPL Site 38.05
Beacon Heights Landfill NPL Site 46.77
Cheshire Ground Water Contamination Deleted NPL Site 35.57
Durham Meadows NPL Site 33.94
Gallup's Quarry NPL Site 46.29
Kellogg-Deering Well Field NPL Site 39.92
Laurel Park, Inc. NPL Site -
New London Submarine Base NPL Site 36.53
Nutmeg Valley Road Deleted NPL Site 42.69
Old Southington Landfill Deleted NPL Site 54.35

Frequently Asked Questions

What is the Linemaster Switch Corp. Superfund site?
Linemaster Switch Corp. is an active National Priorities List (NPL) Superfund site located in Woodstock, CT. It has a Hazard Ranking System (HRS) score of 33.71. Superfund sites are contaminated locations identified by the EPA for long-term cleanup.
Is Linemaster Switch Corp. dangerous to live near?
The presence of a site on the EPA National Priorities List does not by itself indicate an immediate health risk to nearby residents. EPA evaluates sites through a comprehensive process including remedial investigation and risk assessment. Construction of the cleanup remedy has been completed at this site. For site-specific health questions, contact your state environmental or health agency.
What is the HRS score for Linemaster Switch Corp.?
Linemaster Switch Corp. has a Hazard Ranking System (HRS) score of 33.71. The HRS is the EPA's principal mechanism for evaluating Superfund sites, scores of 28.50 or greater qualify for the NPL. Higher scores indicate greater potential risk based on toxicity, waste quantity, release likelihood, and affected population.
What contaminants are at the Linemaster Switch Corp. site?
The EPA has identified 50 contaminants at Linemaster Switch Corp.. Contaminant data is maintained in the EPA's Superfund database and is based on site investigations conducted during the remedial process.
What is the cleanup status of Linemaster Switch Corp.?
Linemaster Switch Corp. is currently NPL Site on the National Priorities List. Construction of the cleanup remedy has been completed. The EPA Superfund cleanup process includes phases from preliminary assessment through post-construction completion.

About Superfund

The National Priorities List (NPL) is the list of sites of national priority among the known releases or threatened releases of hazardous substances, pollutants, or contaminants throughout the United States. The NPL is intended primarily to guide the EPA in determining which sites warrant further investigation.

The Hazard Ranking System (HRS) score is the principal mechanism the EPA uses to evaluate sites for placement on the NPL. Sites with an HRS score of 28.50 or greater are eligible for the NPL. Higher scores indicate greater potential risk.

The EPA's Superfund cleanup process typically follows these phases: preliminary assessment, site inspection, NPL listing, remedial investigation/feasibility study, remedy selection, remedial design/action, construction completion, post-construction completion, and NPL deletion. Some sites remain on the NPL for decades.

PlainEnviro presents this data without advocacy framing. The presence of a site on the NPL does not by itself indicate an immediate health risk to nearby residents. For site-specific health questions, consult your local environmental or health agency.

Related